<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Control Panels Archives - GDSA</title>
	<atom:link href="https://gdsa.co.za/product-category/control-panels/feed/" rel="self" type="application/rss+xml" />
	<link>https://gdsa.co.za/product-category/control-panels/</link>
	<description>Gas Detection Systems Africa</description>
	<lastBuildDate>Thu, 12 Mar 2026 07:29:12 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://gdsa.co.za/wp-content/uploads/2020/08/cropped-gdsa-favicon-32x32.jpg</url>
	<title>Control Panels Archives - GDSA</title>
	<link>https://gdsa.co.za/product-category/control-panels/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>C1-80 Control Panel</title>
		<link>https://gdsa.co.za/product/c1-80-control-panel/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Mon, 09 Feb 2026 13:49:53 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29563</guid>

					<description><![CDATA[<p>The C1 Panel is designed to monitor sensors mounted in a full range of environments from commercial premises through to industrial applications which require hazardous area sensing. Monitor locations are - public buildings, car parks, tunnels, breweries, boiler plant rooms, water treatment works, H&#38;V control, manufacturing, process plants, horticulture, hotels, offices. Please note that the C1 panel is not certified for use in an hazardous environments and is strictly used only to monitor Gas detectors placed in hazardous environments, the panel should be placed inside a suitable IP rated or EX rated enclosure for this purpose. Each sensor connected to the C1 panel will continuously report back to the panel, in the event of a hazardous gas leak the panel LCD will visually display the gas concentration and preset High and Low alarm values, the internal 86 DB alarm buzzer and alarm relays will activate.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/02/C1-80-CONTROL-PANEL-SM.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/c1-80-control-panel/">C1-80 Control Panel</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold"><strong>PRODUCT FEATURES</strong></p>
<p data-pm-slice="0 0 []">The C1-80 Channel control Panel is designed with a high quality lockable Ip64 enclosure to prevent tampering. The C1 panel is a Modbus 64 channel and a Direct sensor 16 Channel controllers with Modbus output. The C1 Panel is a system that supports a network of up to 16 control panels interfacing with repeater panels, relay panels and various GDSA gas sensors to be monitored on a IOT software system if required.</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="whitespace-normal break-words pl-2">IOT interface modules transmitting data to cloud</li>
<li class="whitespace-normal break-words pl-2">Repeater panels interface on Modbus output</li>
<li class="whitespace-normal break-words pl-2">Programmable relays to group sensor</li>
<li class="whitespace-normal break-words pl-2">Self fault diagnostics and fault identifier</li>
</ul>
<p>&nbsp;</p>
<p class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold"><strong>TECHNICAL SPECIFICATIONS</strong></p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Power supply</strong> 220Vac / 50Hz</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Direct sensors</strong> 16 Direct 4-20mA sensors 3wire</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Addressable sensors</strong> 64 Modbus sensors 2 wire</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Cable size</strong> 4-20mA 3 core wire 0.7mm Modbus 4 core wire 1.5mm</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Internal DC supply</strong> 25-28Vdc 5Amp</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>External DC supply</strong> 25-28 Vdc 10Amp min ( Power Booster)</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Alarm settings</strong> 4 Alarm settings High/Low/Fault/24V output Alarm</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Available relays</strong> 8 selectable relays programmable for Group Configuration. 1 Common Relay preset for all High Alarms 1 Fault Relay for Cable break or sensor fault</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Indication</strong> 4 Line 40 character LCD screen Alarm LED, Power LED , Fault LED</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Enclosure</strong> Mild steel Powder coated enclosure with cabinet Lock IP 64 and optional IP 65</p>
<p>&nbsp;</p>
<p>The post <a href="https://gdsa.co.za/product/c1-80-control-panel/">C1-80 Control Panel</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>C1-8 Control Panel</title>
		<link>https://gdsa.co.za/product/c1-8-control-panel/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Mon, 09 Feb 2026 10:47:38 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29560</guid>

					<description><![CDATA[<p>The C1 Panel is designed to monitor sensors mounted in a full range of environments from commercial premises through to industrial applications which require hazardous area sensing. Monitor locations are - public buildings, car parks, tunnels, breweries, boiler plant rooms, water treatment works, H&#38;V control, manufacturing, process plants, horticulture, hotels, offices. Please note that the C1 panel is not certified for use in an hazardous environments and is strictly used only to monitor Gas detectors placed in hazardous environments, the panel should be placed inside a suitable IP rated or EX rated enclosure for this purpose. Each sensor connected to the C1 panel will continuously report back to the panel, in the event of a hazardous gas leak the panel LCD will visually display the gas concentration and preset High and Low alarm values, the internal 86 DB alarm buzzer and alarm relays will activate.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/02/C1-8-CONTROL-PANEL-SM.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/c1-8-control-panel/">C1-8 Control Panel</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold"><strong>PRODUCT FEATURES</strong></p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The C1-8 Channel control Panel is designed with a high quality lockable IP64 enclosure to prevent tampering. The C1-8CH panel has Modbus output and Direct sensor input of 8 x 4-20mA sensors. The C1 Panel is a system that supports a network of up to 16 control panels interfacing with repeater panels, relay panels and various GDSA gas sensors to be monitored on a IOT software system if required.</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="whitespace-normal break-words pl-2">IOT interface modules transmitting data to cloud</li>
<li class="whitespace-normal break-words pl-2">Repeater panels interface on Modbus output</li>
<li class="whitespace-normal break-words pl-2">Programmable relays to group sensor</li>
<li class="whitespace-normal break-words pl-2">Self fault diagnostics and fault identifier</li>
</ul>
<p>&nbsp;</p>
<p class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold"><strong>TECHNICAL SPECIFICATIONS</strong></p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Power supply</strong> 220Vac / 50Hz</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Direct sensors</strong> Up Direct 4-20mA sensors 3wire</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Addressable Cable size</strong> Repeater Panel on Modbus output 4-20mA 3 core wire 1mm</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Internal DC supply</strong> 25 Vdc 5Amp</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>External DC supply</strong> 25 Vdc 10Amp min ( Power Booster)</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Alarm settings</strong> 4 Alarm settings High/Low/Fault/24V output Alarm</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Available relays</strong> 8 selectable relays programmable for Group Configuration. 1 Common Relay preset for all High Alarms 1 Fault Relay for Cable break or sensor fault</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Indication</strong> 4 Line 40 character LCD screen Alarm LED, Power LED , Fault LED</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Enclosure</strong> Mild steel Powder coated enclosure with cabinet Lock IP 64 and optional IP 65</p>
<p>&nbsp;</p>
<p>The post <a href="https://gdsa.co.za/product/c1-8-control-panel/">C1-8 Control Panel</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		