<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>All Gas Detection Products &amp; Data Sheets | GDSA</title>
	<atom:link href="https://gdsa.co.za/all-products/feed/" rel="self" type="application/rss+xml" />
	<link>https://gdsa.co.za/shop/</link>
	<description>Gas Detection Systems Africa</description>
	<lastBuildDate>Thu, 15 Oct 2026 10:36:06 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.10</generator>

<image>
	<url>https://gdsa.co.za/wp-content/uploads/2020/08/cropped-gdsa-favicon-32x32.jpg</url>
	<title>All Gas Detection Products &amp; Data Sheets | GDSA</title>
	<link>https://gdsa.co.za/shop/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SIG-G1-XD-SS</title>
		<link>https://gdsa.co.za/product/sig-g1-xd-ss/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Thu, 19 Feb 2026 07:14:01 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29622</guid>

					<description><![CDATA[<p data-pm-slice="0 0 []">The SIG-G1-XD-SS is designed to detect and monitor H2S,CO,NO,NO2,SO2,NH3,CI,HCI,CO2,H2,CH4,LPG and various Hydrocarbons by using Electrochemical Catalytic and Infrared sensor technology. This detector is best suited for wet and corrosive industrial installations, Coastal and marine and food processing plants, it has alarm data capturing function that will save the alarm value with date and time. The clear LCD display will allow you to see the preset alarm values and the real time value been measured. The SIG-G1-XD-SS has a self diagnostic software to identify faults with the sensors and faults with the wire ways. The digital sensor output is linear to the sensor reading with fast response ranging from 2-5 seconds depending on sensor type being used.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/02/SIG-G1-XD-SS.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/sig-g1-xd-ss/">SIG-G1-XD-SS</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Technical Data</h3>
<ul>
<li><strong>Alarm points:</strong> 2 x Relay outputs + Fault alarm Signal</li>
<li><strong>Output:</strong> 4-20mA 3 wire or Modbus Rtu</li>
<li><strong>Sensor Type:</strong> Toxic, Oxygen, Flammable &amp; NDIR</li>
<li><strong>Vdc Supply:</strong> 12-24 Regulated Voltage supply</li>
<li><strong>Indicators:</strong> Alarm, Fault, Power, LCD</li>
<li><strong>Memory:</strong> Alarm memory with time and date</li>
<li><strong>Adjustments:</strong> Non intrusive magnetic switch</li>
<li><strong>Size:</strong> W114 x D94 x H190</li>
<li><strong>Material:</strong> Stainless steel</li>
<li><strong>Sensor Head:</strong> Material stainless steel</li>
<li><strong>Calibration:</strong> One man non intrusive</li>
<li><strong>Fault display:</strong> Sensor and Signal Fault on LCD + LED</li>
<li><strong>IP:</strong> Weather proof IP 65</li>
</ul>
<h3>Product Certification</h3>
<ul>
<li>Product Name<strong>:</strong> SIG-G1-XD-SS</li>
<li>SANAS 60079-0:2012 Ed 5 IEC60079-0:201:1 Ed 6</li>
<li>SANAS 60079-1:2015 Ed 6 IEC60079-1:2014 Ed 7</li>
<li>Product Marking: EX da II T4 Ga / EX da I T4 Ma</li>
</ul>
<h3>Product Info</h3>
<p>The SIG-G1-XD has 2 alarm relay outputs contacts NO/COM/NC. Alarms are NON Latching and will reset relay and indicator LED when gas dissipates.</p>
<p>The post <a href="https://gdsa.co.za/product/sig-g1-xd-ss/">SIG-G1-XD-SS</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>4G-GPS Gas Tracker</title>
		<link>https://gdsa.co.za/product/4g-gps-gas-tracker/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Wed, 18 Feb 2026 07:27:53 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29611</guid>

					<description><![CDATA[<p data-pm-slice="0 0 []">The Gas Tracker is a 4G-GPS Gas monitor that can detect up to 24 different types of gasses using various sensor technology. The Gas Tracker is completely wireless and uses cell towers to transmit data to a Cloud Capture platform. The data can be retrieved real time from a mobile device connected to any wifi platform. The Cloud software offers an array of functions from Real time visual location on google maps, time series graphs, real time alarm indication and past data that can be printed from log. Alarm indication can include emails and sms alarm values. The monitor has a Alarm extension to activate an Audio Visual alarm Buzzer with reset and mute button function. For further information please contact sales agent at GDSA.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/02/4G-GAS-TRACKER.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/4g-gps-gas-tracker/">4G-GPS Gas Tracker</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Features</h3>
<ul>
<li>Cloud capture IOT</li>
<li>GPS Real time location</li>
<li>4G data processing</li>
<li>Onboard data logging</li>
<li>One man Calibration</li>
<li>Sensors for 24 gas types</li>
<li>Corrosion resistant</li>
</ul>
<h3>Certification / Flam</h3>
<ul>
<li>SANAS 60079-0:2012 Ed 5</li>
<li>IEC60079-0:201:1 Ed 6</li>
<li>SANAS 60079-1:2015 Ed 6</li>
<li>IEC60079-1: 2014 Ed 7</li>
</ul>
<h3>Markings</h3>
<ul>
<li>EX da II T4 Ga</li>
<li>EX da I T4 Ma</li>
</ul>
<h3>Enclosure</h3>
<ul>
<li>IP 66, 67, 68 IEC 60947-7-2</li>
<li>SANAS /IEC/BS EN 62262 1K 10</li>
</ul>
<h3>Battery Power</h3>
<ul>
<li>3.7Vdc / 20 Ah Lithium ion</li>
<li>Solar panel supplied with mounting pole and bracket as extra added item.</li>
</ul>
<h3>Sensor / Head / Holder</h3>
<ul>
<li>For volatile gasses we offer a stainless steel head and stainless steel filter suitable for mining, oil and gas industries.</li>
</ul>
<p>The post <a href="https://gdsa.co.za/product/4g-gps-gas-tracker/">4G-GPS Gas Tracker</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SP-SECURE</title>
		<link>https://gdsa.co.za/product/sp-secure/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Fri, 13 Feb 2026 09:34:14 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29599</guid>

					<description><![CDATA[<p>SP secure is designed to be suitable for leak detection of any gas piping and valves by equipping a built-in sampling pump. Since the measured gas concentration is displayed in digital numbers, an accurate Measuring Type is possible.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/01/Datasheet_SP-secure_En.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/sp-secure/">SP-SECURE</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Key Features</h3>
<p><strong>Sampling pump built-in structure:</strong> Integrated sampling pump enables leak detection in gas piping and valves.</p>
<p><strong>The digital concentration display:</strong> LCD display shows measured gas concentration in digital numbers for accurate readings.</p>
<p><strong>Detector for the gas leakage:</strong> Specifically designed for detecting gas leaks in piping systems and valves.</p>
<p><strong>Both rechargeable batteries and alkaline batteries are compatible:</strong> Flexible power options with rechargeable Ni-MHY or AA alkaline batteries.</p>
<p><strong>Adopt the sensor which detects the low concentrated:</strong> Utilizes sensors capable of detecting low gas concentrations for enhanced sensitivity.</p>
<p>&nbsp;</p>
<p>The post <a href="https://gdsa.co.za/product/sp-secure/">SP-SECURE</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SP-MGT</title>
		<link>https://gdsa.co.za/product/sp-mgt/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Fri, 13 Feb 2026 09:31:51 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29598</guid>

					<description><![CDATA[<p>MGT Multi-Gas Detector is designed to protect workers from the most common industrial hazards, including oxygen deficiency, toxic gas poisoning, and explosions. It continuously measures four key gases O2, CO, H2S, and combustible gas (CH4) displaying their concentrations and raising alarms (visual, audible, and vibrating) when dangerous levels are detected. Equipped with a dual CO/H2S sensor, MGT ensures reliable monitoring to safeguard workers in hazardous environments.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/01/Brochure_En_MGT.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/sp-mgt/">SP-MGT</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>Key Features</h4>
<p><strong>Small dimension &amp; lightweight:</strong> Compact and portable design for easy carrying and comfortable wear.</p>
<p><strong>Rechargeable battery:</strong> Rechargeable Li-ion battery (2,000mAh) eliminates the need for frequent battery replacements.</p>
<p><strong>30EA of bump tests / events / cal.:</strong> Stores 30 bump test logs, event logs, and calibration logs for comprehensive tracking.</p>
<p><strong>Simultaneously detect 4 different gases:</strong> Monitors O2, CO, H2S, and combustible gas (CH4) at the same time.</p>
<p><strong>25 hours use by one charge for 4-6 hours (P-Type):</strong> Extended battery life for P-Type model with 25 hours of continuous operation.</p>
<p><strong>60 days use by one charge for 4-5 hours (N-Type):</strong> Exceptional battery life for N-Type model with up to 60 days of continuous operation.</p>
<p><strong>Configuration via exclusive IR Link:</strong> Easy device configuration and data management through IR Link communication.</p>
<p><strong>Easy check &amp; calibration via Docking Station:</strong> Simplified maintenance with single or multi docking station for calibration and bump testing.</p>
<p><strong>Intrinsic safety:</strong> Explosion-proof certification ensures safe operation in hazardous environments.</p>
<p>&nbsp;</p>
<h3>Certification</h3>
<p><strong>IECEx:</strong> Ex ia IIC T4 Ga (SP-MGT-N) &#8211; Ex da ia IIC T4 Ga (SP-MGT-P)</p>
<p><strong>ATEX:</strong> II 1 G Ex ia IIC T4 Ga (SP-MGT-N) &#8211; II 1 G Ex da ia IIC T4 Ga (SP-MGT-P)</p>
<p><strong>CSA/UL:</strong> Ex ia IIC T4 Ga (SP-MGT-N), Class I, Division 1, Groups A, B, C, and/or D, T4, Class I, Zone 0, AEx ia IIC T4 Ga &#8211; Ex da ia IIC T4 Ga (SP-MGT-P), Class I, Division 1, Groups A, B, C, and/or D, T4, Class I, Zone 0, AEx da ia IIC T4 Ga</p>
<p><strong>CNEx &amp; CPA:</strong> Ex ia llC 54 Ga (SP-MGT-N) &#8211; EX da ia llC T4 Ga (SP-MGT-P)</p>
<p><strong>INMETRO:</strong> Ex ia IIC T4 Ga (SP-MGT-N) &#8211; Ex da ia IIC T4 Ga (SP-MGT-P)</p>
<p><strong>PESO:</strong> Ex ia IIC T4 Ga (SP-MGT-N) &#8211; Ex da ia IIC T4 Ga (SP-MGT-P)</p>
<p><strong>etc.:</strong> RoHs2, EMC, RCM(ACMA&amp;RSM), REACH, WEEE, FCC</p>
<p>The post <a href="https://gdsa.co.za/product/sp-mgt/">SP-MGT</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SP-MGTP</title>
		<link>https://gdsa.co.za/product/sp-mgtp/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Fri, 13 Feb 2026 09:27:17 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29595</guid>

					<description><![CDATA[<p>SP-MGTP is a sampling-type multi-gas detector capable of monitoring up to 6 gases with 37 possible gas combinations, including Volatile Organic Compounds (VOC). It continuously detects oxygen (O₂), toxic, flammable gases, and VOCs, providing real-time alerts through LED indicators, sound alarms, and vibration signals. Designed to prevent industrial accidents caused by hazardous gas exposure, this device offers reliable protection in demanding environments.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/01/Brochure_En_SP-MGTP.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/sp-mgtp/">SP-MGTP</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>Key Features</h4>
<p><strong>Sampling-type with embedded pump &amp; probe:</strong> Built-in pump and probe for efficient gas sampling in hard-to-reach areas.</p>
<p><strong>Max 6 gases with 37 different gas combinations:</strong> Flexible configuration to monitor up to 6 gases simultaneously with 37 possible combinations.</p>
<p><strong>Event log (Recent 30 event / bump / calibration):</strong> Stores the 30 most recent alarm events, bump tests, and calibration records for tracking and audits.</p>
<p><strong>Easy to maintain (2 filters in probe &amp; in detector):</strong> Dual-filter system in both probe and detector for simple maintenance and extended device life.</p>
<p><strong>Inner teflon coating of gas tube line:</strong> Teflon-coated gas tube line prevents contamination and ensures accurate readings.</p>
<p>The post <a href="https://gdsa.co.za/product/sp-mgtp/">SP-MGTP</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DUO TRACER</title>
		<link>https://gdsa.co.za/product/duo-tracer/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Fri, 13 Feb 2026 09:23:21 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29593</guid>

					<description><![CDATA[<p>DUO TRACER is a portable gas detector that uses the diffusion method to warn of dangerous environments related to gases. The detector indicates the concentration of oxygen, explosive or toxic gases on the LCD monitor. It is easy and simple to operate. The device alerts workers to danger with an alarm, LED, and vibration when gas levels exceed safety thresholds. It shows the gas concentration in real time and identifies the maximum and minimum concentration. Settings can be modified via wireless or Senko IR Link (optional).</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/01/Brochure_En_DUO-TRACER.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/duo-tracer/">DUO TRACER</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>Key Features</h4>
<p><strong>Dual Gas Detection:</strong> Simultaneously detects two gases for comprehensive monitoring.</p>
<p><strong>Wireless and IR Connectivity:</strong> Easy connection and configuration.</p>
<p><strong>Real-time Monitoring:</strong> Continuous gas concentration readings.</p>
<p><strong>IP67 Rating:</strong> Water and dustproof for rugged environments.</p>
<p><strong>Compact and Lightweight:</strong> Portable design for easy handling.</p>
<p><strong>High-performance Alarms:</strong> Visual, audible, and vibration alerts.</p>
<p><strong>Event Log:</strong> Automatically logs up to 30 alarm events.</p>
<p><strong>IR Link Configuration:</strong> Easy data management and setup.</p>
<p><strong>User-friendly Operation:</strong> Simple interface for ease of use.</p>
<p><strong>Multi-docking Station:</strong> Simultaneous bump test and calibration.</p>
<p><strong>Explosion-proof Certification:</strong> Complies with global explosion-proof standard.</p>
<p>&nbsp;</p>
<h3>Certification</h3>
<p><strong>IECEx:</strong> IECEx KSCP 24.0025X &#8211; DUO TRACER-1 to 2: Ex ia op is IIC T4 Ga &#8211; DUO TRACER-3 to 16: Ex ia IIC T4 Ga</p>
<p><strong>ATEX:</strong> KSCP 24ATEX0016X &#8211; DUO TRACER-1 to 2: Ex ia op is IIC T4 Ga &#8211; DUO TRACER-3 to 16: Ex ia IIC T4 Ga</p>
<p><strong>CSA/UL:</strong> LC24CA22376-1 &#8211; DUO TRACER-1 to 2: Ex ia op is IIC T4 Ga &#8211; DUO TRACER-3 to 16: Ex ia IIC T4 Ga</p>
<p><strong>CNEx &amp; CPA:</strong> 24.4201X &#8211; DUO TRACER-1 to 2: Ex ia op is IIC T4 Ga &#8211; DUO TRACER-3 to 16: Ex ia IIC T4 Ga</p>
<p><strong>KCs:</strong> 24-GA2BO-0613X &#8211; DUO TRACER-1 to 2: Ex ia IIC T4 Ga &#8211; 24-GA2BO-0612X &#8211; DUO TRACER-3 to 16: Ex ia IIC T4 Ga</p>
<p><strong>etc.:</strong> RoHs2, FCC(DUO TRACER 1 to 15), EMC(DUO TRACER 1 to 15)</p>
<p>The post <a href="https://gdsa.co.za/product/duo-tracer/">DUO TRACER</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SP-SGT-P</title>
		<link>https://gdsa.co.za/product/sp-sgt-p/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Fri, 13 Feb 2026 08:56:39 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29592</guid>

					<description><![CDATA[<p>SGT-P is a single replaceable gas detector designed to detect oxygen deficiency and the presence of toxic gas in the ambient environment. SGT-P is the replaceable type of gas sensor and battery. When activated, SGT-P continuously monitors ambient air for the presence of a specific gas and alerts the user to potentially unsafe exposure with LED, vibrating, and audible alarms in the event that gas concentration exceeds alarm set points.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/01/Brochure_En_SGT-P.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/sp-sgt-p/">SP-SGT-P</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h1></h1>
<h2>Key Features</h2>
<p><strong>Sensor and battery replacement available:</strong> Replaceable gas sensor and battery for extended device lifespan and cost-effective maintenance.</p>
<p><strong>Power on / off functionality:</strong> Convenient power control for when the detector is not in use.</p>
<p><strong>Configuration via exclusive IR Link:</strong> Easy configuration and data download through IR Link communication.</p>
<p><strong>Maintenance-free operation for CO and H₂S model:</strong> No calibration needed for 2 years, reducing maintenance requirements and costs.</p>
<p>&nbsp;</p>
<h2>Certification</h2>
<p><strong>IECEx:</strong> Ex ia llC T4 Ga</p>
<p><strong>ATEX:</strong> II 1 G Ex ia IIC T4 Ga</p>
<p><strong>CSA/UL:</strong> Ex ia llC T4 Ga &#8211; Class I, Zone 0, AEx ia IIC T4 Ga &#8211; Class I, Division 1, Groups A, B, C, D, T4</p>
<p><strong>CNEx &amp; CPA:</strong> Ex ia llC T4 Ga</p>
<p><strong>INMETRO:</strong> Ex ia llC T4 Ga</p>
<p><strong>PESO:</strong> Ex ia llC T4 Ga</p>
<p><strong>etc.:</strong> RoHs2, RCM, REACH, WEEE, FCC</p>
<p>The post <a href="https://gdsa.co.za/product/sp-sgt-p/">SP-SGT-P</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>V-Pro Benzene</title>
		<link>https://gdsa.co.za/product/v-pro-benzene/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Fri, 13 Feb 2026 08:52:20 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29591</guid>

					<description><![CDATA[<p>V-Pro Benzene is a portable detector designed for precise Benzene monitoring in hazardous environments. Featuring a dedicated Benzene gas tube and an integrated pump for efficient sampling in confined spaces, it provides real-time data on the LCD screen. Alerts are given through audible, visual, and vibratory alarms when gas levels exceed safety thresholds. With Senko IR-LINK or Short-range wireless communication, it offers seamless data management and easy operation.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/01/Brochure_En_V-Pro-Benzene.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/v-pro-benzene/">V-Pro Benzene</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Key Features</h3>
<p><strong>Real-time Benzene Detection:</strong> Continuously monitors Benzene levels with immediate LCD feedback for rapid response.</p>
<p><strong>Gas Tube for Benzene Detection:</strong> Specifically designed for Benzene measurement, ensuring precise and reliable detection.</p>
<p><strong>Easy Benzene Tube Replacement:</strong> Easily replaceable Benzene tube for quick maintenance without tools or downtime.</p>
<p><strong>Built-in Pump:</strong> Integrated pump for efficient sampling, ideal for confined spaces and hard-to-reach areas.</p>
<p><strong>Wireless and IR Connectivity:</strong> Supports wireless adjustments and data transfer via Senko IR-LINK or Short-range wireless communication.</p>
<p><strong>Durability:</strong> IP67-rated case provides superior protection against dust and water, ensuring reliable performance in harsh environments.</p>
<p><strong>Extended Battery Life:</strong> Up to 60 hours of continuous operation on a single charge.</p>
<p><strong>High-Performance Alarms:</strong> Audible, visual, and vibratory alarms for immediate alerts when Benzene levels exceed safe thresholds.</p>
<p><strong>Event Logging:</strong> Logs up to 30 events for easy tracking and safety audits.</p>
<p><strong>User-Friendly Interface:</strong> Four-button operation for quick access to settings, gas data, and alarms.</p>
<p><strong>Explosion-proof Certification:</strong> Certified for use in oil &amp; gas, chemical, and mining environments, ensuring safe operation in explosive atmospheres.</p>
<h3>Certification</h3>
<p><strong>IECEx:</strong> Ex ia IIC T4 Ga &#8211; Certified for use in explosive atmospheres in industrial environments.</p>
<p><strong>ATEX:</strong> II 1 G Ex ia IIC T4 Ga &#8211; ATEX certified for safe operation in hazardous gas environments.</p>
<p><strong>CSA/UL:</strong> Class I, Zone 0, AEx ia IIC T4 Ga &#8211; Class I, Division 1, Groups A, B, C, D, T4 &#8211; Ex ia IIC T4 Ga &#8211; -20 ºC &lt; Ta &lt; +50 ºC</p>
<p><strong>CNEx:</strong> Ex ia llC T4 Ga</p>
<p>The post <a href="https://gdsa.co.za/product/v-pro-benzene/">V-Pro Benzene</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>C1-80 Control Panel</title>
		<link>https://gdsa.co.za/product/c1-80-control-panel/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Mon, 09 Feb 2026 13:49:53 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29563</guid>

					<description><![CDATA[<p>The C1 Panel is designed to monitor sensors mounted in a full range of environments from commercial premises through to industrial applications which require hazardous area sensing. Monitor locations are - public buildings, car parks, tunnels, breweries, boiler plant rooms, water treatment works, H&#38;V control, manufacturing, process plants, horticulture, hotels, offices. Please note that the C1 panel is not certified for use in an hazardous environments and is strictly used only to monitor Gas detectors placed in hazardous environments, the panel should be placed inside a suitable IP rated or EX rated enclosure for this purpose. Each sensor connected to the C1 panel will continuously report back to the panel, in the event of a hazardous gas leak the panel LCD will visually display the gas concentration and preset High and Low alarm values, the internal 86 DB alarm buzzer and alarm relays will activate.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/02/C1-80-CONTROL-PANEL-SM.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/c1-80-control-panel/">C1-80 Control Panel</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold"><strong>PRODUCT FEATURES</strong></p>
<p data-pm-slice="0 0 []">The C1-80 Channel control Panel is designed with a high quality lockable Ip64 enclosure to prevent tampering. The C1 panel is a Modbus 64 channel and a Direct sensor 16 Channel controllers with Modbus output. The C1 Panel is a system that supports a network of up to 16 control panels interfacing with repeater panels, relay panels and various GDSA gas sensors to be monitored on a IOT software system if required.</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="whitespace-normal break-words pl-2">IOT interface modules transmitting data to cloud</li>
<li class="whitespace-normal break-words pl-2">Repeater panels interface on Modbus output</li>
<li class="whitespace-normal break-words pl-2">Programmable relays to group sensor</li>
<li class="whitespace-normal break-words pl-2">Self fault diagnostics and fault identifier</li>
</ul>
<p>&nbsp;</p>
<p class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold"><strong>TECHNICAL SPECIFICATIONS</strong></p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Power supply</strong> 220Vac / 50Hz</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Direct sensors</strong> 16 Direct 4-20mA sensors 3wire</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Addressable sensors</strong> 64 Modbus sensors 2 wire</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Cable size</strong> 4-20mA 3 core wire 0.7mm Modbus 4 core wire 1.5mm</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Internal DC supply</strong> 25-28Vdc 5Amp</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>External DC supply</strong> 25-28 Vdc 10Amp min ( Power Booster)</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Alarm settings</strong> 4 Alarm settings High/Low/Fault/24V output Alarm</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Available relays</strong> 8 selectable relays programmable for Group Configuration. 1 Common Relay preset for all High Alarms 1 Fault Relay for Cable break or sensor fault</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Indication</strong> 4 Line 40 character LCD screen Alarm LED, Power LED , Fault LED</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Enclosure</strong> Mild steel Powder coated enclosure with cabinet Lock IP 64 and optional IP 65</p>
<p>&nbsp;</p>
<p>The post <a href="https://gdsa.co.za/product/c1-80-control-panel/">C1-80 Control Panel</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>C1-8 Control Panel</title>
		<link>https://gdsa.co.za/product/c1-8-control-panel/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Mon, 09 Feb 2026 10:47:38 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29560</guid>

					<description><![CDATA[<p>The C1 Panel is designed to monitor sensors mounted in a full range of environments from commercial premises through to industrial applications which require hazardous area sensing. Monitor locations are - public buildings, car parks, tunnels, breweries, boiler plant rooms, water treatment works, H&#38;V control, manufacturing, process plants, horticulture, hotels, offices. Please note that the C1 panel is not certified for use in an hazardous environments and is strictly used only to monitor Gas detectors placed in hazardous environments, the panel should be placed inside a suitable IP rated or EX rated enclosure for this purpose. Each sensor connected to the C1 panel will continuously report back to the panel, in the event of a hazardous gas leak the panel LCD will visually display the gas concentration and preset High and Low alarm values, the internal 86 DB alarm buzzer and alarm relays will activate.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/02/C1-8-CONTROL-PANEL-SM.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/c1-8-control-panel/">C1-8 Control Panel</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold"><strong>PRODUCT FEATURES</strong></p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]">The C1-8 Channel control Panel is designed with a high quality lockable IP64 enclosure to prevent tampering. The C1-8CH panel has Modbus output and Direct sensor input of 8 x 4-20mA sensors. The C1 Panel is a system that supports a network of up to 16 control panels interfacing with repeater panels, relay panels and various GDSA gas sensors to be monitored on a IOT software system if required.</p>
<ul class="[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3">
<li class="whitespace-normal break-words pl-2">IOT interface modules transmitting data to cloud</li>
<li class="whitespace-normal break-words pl-2">Repeater panels interface on Modbus output</li>
<li class="whitespace-normal break-words pl-2">Programmable relays to group sensor</li>
<li class="whitespace-normal break-words pl-2">Self fault diagnostics and fault identifier</li>
</ul>
<p>&nbsp;</p>
<p class="text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold"><strong>TECHNICAL SPECIFICATIONS</strong></p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Power supply</strong> 220Vac / 50Hz</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Direct sensors</strong> Up Direct 4-20mA sensors 3wire</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Addressable Cable size</strong> Repeater Panel on Modbus output 4-20mA 3 core wire 1mm</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Internal DC supply</strong> 25 Vdc 5Amp</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>External DC supply</strong> 25 Vdc 10Amp min ( Power Booster)</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Alarm settings</strong> 4 Alarm settings High/Low/Fault/24V output Alarm</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Available relays</strong> 8 selectable relays programmable for Group Configuration. 1 Common Relay preset for all High Alarms 1 Fault Relay for Cable break or sensor fault</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Indication</strong> 4 Line 40 character LCD screen Alarm LED, Power LED , Fault LED</p>
<p class="font-claude-response-body break-words whitespace-normal leading-[1.7]"><strong>Enclosure</strong> Mild steel Powder coated enclosure with cabinet Lock IP 64 and optional IP 65</p>
<p>&nbsp;</p>
<p>The post <a href="https://gdsa.co.za/product/c1-8-control-panel/">C1-8 Control Panel</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>