<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Hazardous Gas Detectors Archives - GDSA</title>
	<atom:link href="https://gdsa.co.za/product-category/hazardous-gas-detectors/feed/" rel="self" type="application/rss+xml" />
	<link>https://gdsa.co.za/product-category/hazardous-gas-detectors/</link>
	<description>Gas Detection Systems Africa</description>
	<lastBuildDate>Wed, 25 Mar 2026 11:00:46 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://gdsa.co.za/wp-content/uploads/2020/08/cropped-gdsa-favicon-32x32.jpg</url>
	<title>Hazardous Gas Detectors Archives - GDSA</title>
	<link>https://gdsa.co.za/product-category/hazardous-gas-detectors/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SIG-G1-XD-SS</title>
		<link>https://gdsa.co.za/product/sig-g1-xd-ss/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Thu, 19 Feb 2026 07:14:01 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29622</guid>

					<description><![CDATA[<p data-pm-slice="0 0 []">The SIG-G1-XD-SS is designed to detect and monitor H2S,CO,NO,NO2,SO2,NH3,CI,HCI,CO2,H2,CH4,LPG and various Hydrocarbons by using Electrochemical Catalytic and Infrared sensor technology. This detector is best suited for wet and corrosive industrial installations, Coastal and marine and food processing plants, it has alarm data capturing function that will save the alarm value with date and time. The clear LCD display will allow you to see the preset alarm values and the real time value been measured. The SIG-G1-XD-SS has a self diagnostic software to identify faults with the sensors and faults with the wire ways. The digital sensor output is linear to the sensor reading with fast response ranging from 2-5 seconds depending on sensor type being used.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/02/SIG-G1-XD-SS.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/sig-g1-xd-ss/">SIG-G1-XD-SS</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Technical Data</h3>
<ul>
<li><strong>Alarm points:</strong> 2 x Relay outputs + Fault alarm Signal</li>
<li><strong>Output:</strong> 4-20mA 3 wire or Modbus Rtu</li>
<li><strong>Sensor Type:</strong> Toxic, Oxygen, Flammable &amp; NDIR</li>
<li><strong>Vdc Supply:</strong> 12-24 Regulated Voltage supply</li>
<li><strong>Indicators:</strong> Alarm, Fault, Power, LCD</li>
<li><strong>Memory:</strong> Alarm memory with time and date</li>
<li><strong>Adjustments:</strong> Non intrusive magnetic switch</li>
<li><strong>Size:</strong> W114 x D94 x H190</li>
<li><strong>Material:</strong> Stainless steel</li>
<li><strong>Sensor Head:</strong> Material stainless steel</li>
<li><strong>Calibration:</strong> One man non intrusive</li>
<li><strong>Fault display:</strong> Sensor and Signal Fault on LCD + LED</li>
<li><strong>IP:</strong> Weather proof IP 65</li>
</ul>
<h3>Product Certification</h3>
<ul>
<li>Product Name<strong>:</strong> SIG-G1-XD-SS</li>
<li>SANAS 60079-0:2012 Ed 5 IEC60079-0:201:1 Ed 6</li>
<li>SANAS 60079-1:2015 Ed 6 IEC60079-1:2014 Ed 7</li>
<li>Product Marking: EX da II T4 Ga / EX da I T4 Ma</li>
</ul>
<h3>Product Info</h3>
<p>The SIG-G1-XD has 2 alarm relay outputs contacts NO/COM/NC. Alarms are NON Latching and will reset relay and indicator LED when gas dissipates.</p>
<p>The post <a href="https://gdsa.co.za/product/sig-g1-xd-ss/">SIG-G1-XD-SS</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SIG-G1-XDM (Modbus)</title>
		<link>https://gdsa.co.za/product/sig-g1-xdm/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Mon, 09 Feb 2026 09:47:56 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29554</guid>

					<description><![CDATA[<p>The SIG-G1-XDM (Modbus) is designed to detect and monitor H2S,CO,NO,NO2,SO2,NH3,Cl,HCl,CO2,H2,CH4,LPG and various Hydrocarbons by using Electrochemical Catalytic and Infrared sensor technology. This detector is used in the Industrial and commercial industry, it has alarm data capturing function that will save the alarm value with date and time. The clear LCD display will allow you to see the preset alarm values and the real time value been measured. The SIG-G1-XDM has a self diagnostic software to identify faults with the sensors and faults with the signalling. The digital sensor output is linear to the sensor reading with fast response ranging from 2-5 seconds depending on sensor type being used.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/02/SIG-G1-XDM-MODBUS.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/sig-g1-xdm/">SIG-G1-XDM (Modbus)</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Technical Data</strong><br />
Alarm points &#8211; 1 x Relay outputs + Fault alarm Signal output Standard Modbus RTU<br />
Sensor Type &#8211; Toxic, Oxygen, Flammable &amp; NDIR<br />
Vdc Supply &#8211; 12-24 Regulated Voltage supply<br />
Indicators &#8211; Alarm, Fault, Power, LCD<br />
Memory &#8211; Alarm memory with time and date<br />
Adjustments &#8211; Non intrusive magnetic switch<br />
Size &#8211; W114 x D94 x H190<br />
Material &#8211; Aluminum Alloy Powder coated<br />
Sensor Head &#8211; Material stainless steel<br />
Calibration &#8211; One man non intrusive<br />
Fault display &#8211; Sensor and Signal Fault on LCD + LED<br />
IP &#8211; Weather proof IP 65</p>
<p><strong>PRODUCT CERTIFICATION</strong><br />
Product Name: SIG-G1-XDM<br />
SANAS 60079-0:2012 Ed 5<br />
IEC60079-0:201:1 Ed 6<br />
SANAS60079-1:2015 Ed 6<br />
IEC60079-1:2014Ed 7<br />
PRODUCT MARKING: EX da II T4 Ga / EX da I T4 Ma</p>
<p><strong>Product Info</strong><br />
The SIG-G1-XDM has 1 alarm relay output contacts NO/COM/NC .<br />
Alarms are NON Latching and will reset relay and indicator LED when gas clears/leaks.</p>
<p>The post <a href="https://gdsa.co.za/product/sig-g1-xdm/">SIG-G1-XDM (Modbus)</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SIG-G1-XD (4-20mA)</title>
		<link>https://gdsa.co.za/product/sig-g1-xd/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Mon, 09 Feb 2026 09:12:23 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29553</guid>

					<description><![CDATA[<p>The SIG-G1-XD (4-20mA) is designed to detect and monitor H2S,CO,NO,NO2,SO2,NH3,Cl,HCl,CO2,H2,CH4,LPG and various Hydrocarbons by using Electrochemical Catalytic and Infrared sensor technology. This detector is used in the Industrial and commercial industry, it has alarm data capturing function that will save the alarm value with date and time. The clear LCD display will allow you to see the preset alarm values and the real time value been measured. The SIG-G1-XD has a self diagnostic software to identify faults with the sensors and faults with the signaling. The digital sensor output is linear to the sensor reading with fast response ranging from 2-5 seconds depending on sensor type being used.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/02/SIG-G1-XD-4-20mA-R8.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/sig-g1-xd/">SIG-G1-XD (4-20mA)</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Technical Data</strong><br />
Alarm points &#8211; 2 x Relay outputs + Fault alarm Signal output 4-20mA 3 wire signal output<br />
Sensor Type &#8211; Toxic, Oxygen, Flammable &amp; NDIR<br />
Vdc Supply &#8211; 12-24 Regulated Voltage supply<br />
Indicators &#8211; Alarm, Fault, Power, LCD<br />
Memory &#8211; Alarm memory with time and date<br />
Adjustments &#8211; Non intrusive magnetic switch<br />
Size &#8211; W114 x D94 x H190<br />
Material &#8211; Aluminum Alloy Powder coated<br />
Sensor Head &#8211; Material stainless steel<br />
Calibration &#8211; One man non intrusive<br />
Fault display &#8211; Sensor and Signal Fault on LCD + LED<br />
IP &#8211; Weather proof IP 65</p>
<p><strong>PRODUCT CERTIFICATION</strong><br />
Product Name: SIG-G1-XD<br />
SANAS 60079-0:2012 Ed 5<br />
IEC60079-0:201:1 Ed 6<br />
SANAS60079-1:2015 Ed 6<br />
IEC60079-1:2014Ed 7<br />
PRODUCT MARKING: EX da II T4 Ga / EX da I T4 Ma</p>
<p><strong>Product Info</strong><br />
The SIG-G1-XD has 2 alarm relay outputs contacts NO/COM/NC.<br />
Alarms are NON Latching and will reset relay and indicator LED when gas dissipates.</p>
<p>The post <a href="https://gdsa.co.za/product/sig-g1-xd/">SIG-G1-XD (4-20mA)</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SIG-G1-F</title>
		<link>https://gdsa.co.za/product/sig-g1-f/</link>
		
		<dc:creator><![CDATA[Konner Ackerman]]></dc:creator>
		<pubDate>Fri, 06 Feb 2026 09:51:50 +0000</pubDate>
				<guid isPermaLink="false">https://gdsa.co.za/?post_type=product&#038;p=29494</guid>

					<description><![CDATA[<p>The SIG-G1-F is designed to detect and monitor gases H2S,CO,NO,NO2,SO2,NH3,Cl,HCl,CO2,H2,CH4,LPG and various Hydrocarbons by using Electrochemical Catalytic and Infrared sensor technology. This detector is used in the industrial and commercial industry, it has alarm data capturing function that will save the alarm value with date and time. The clear LCD display will allow you to see the preset alarm values and the real time value been measured. The SIG-G1-F has a self diagnostic software to identify faults with the sensors and faults with the signaling. The digital sensor output is linear to the sensor reading with fast response ranging from 2-5 seconds depending on sensor type being used.</p>
<p><a class="elementor-button elementor-button-link elementor-size-sm" href="https://gdsa.co.za/wp-content/uploads/2026/02/SIG-G1-F-DATA-REV-7.pdf" target="_blank" rel="noopener"><br />
<span class="elementor-button-content-wrapper"><br />
<span class="elementor-button-text">Download Data Sheet</span><br />
</span><br />
</a></p>
<p>The post <a href="https://gdsa.co.za/product/sig-g1-f/">SIG-G1-F</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Technical Data</strong></p>
<p>Alarm points: 1 x Relay outputs + Fault alarm<br />
Signal output: 4-20mA 3 wire signal output<br />
Sensor Type: Toxic, Oxygen, Flammable<br />
Vdc Supply: 12-24 Regulated Voltage supply<br />
Indicators: Alarm, Fault, Power, LCD<br />
Memory: Alarm memory with time and date<br />
Adjustments: 3 Button sequence<br />
Size: W114 x D94 x H190<br />
Material: Aluminum Alloy Powder coated<br />
Sensor Head Material: stainless steel<br />
Calibration: One man, When area is safe<br />
Fault display: Sensor and Signal Fault on LED<br />
IP: Weather proof IP 65</p>
<p><strong>Product Certification</strong></p>
<p>Product Name: SIG-G1-F<br />
SANAS 60079-0:2012 Ed 5<br />
IEC60079-0:2011:1 Ed 6<br />
SANAS60079-1:2015 Ed 6<br />
IEC60079-1:2014Ed 7<br />
PRODUCT MARKING: EX da II T4 Ga / EX da I T4 Ma</p>
<p>The post <a href="https://gdsa.co.za/product/sig-g1-f/">SIG-G1-F</a> appeared first on <a href="https://gdsa.co.za">GDSA</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
